{"id":1283,"date":"2025-09-09T09:17:28","date_gmt":"2025-09-09T09:17:28","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1283"},"modified":"2025-12-01T06:36:34","modified_gmt":"2025-12-01T06:36:34","slug":"type-1-surge-protection-device","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ar\/product\/type-1-surge-protection-device\/","title":{"rendered":"\u062c\u0647\u0627\u0632 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0645\u0646 \u0627\u0644\u0646\u0648\u0639 1 KYSPD-25T1-1P | \u0643\u0648\u0627\u0646\u062c\u064a\u0627"},"content":{"rendered":"<section id=\"overview\">\u0625\u0646 <strong>\u062c\u0647\u0627\u0632 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0645\u0646 \u0627\u0644\u0646\u0648\u0639 1<\/strong> KYSPD-25T1-1P is designed for main distribution boards and service entrances. It protects low-voltage AC installations against direct lightning currents and high-energy surges per IEC\/EN 61643-11. With an impulse discharge current rating of 25 kA per pole (10\/350 \u03bcs), it provides robust first-stage protection in coordinated systems.<\/section>\n<section id=\"features\">\n<h3>\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h3>\n<ul>\n<li>Complies with IEC\/EN 61643-11, Class I \/ Type 1.<\/li>\n<li>Impulse discharge current Iimp: <strong>25 kA (10\/350 \u03bcs)<\/strong>; In 25 kA; Imax 100 kA.<\/li>\n<li>Uc options: 320 V, 385 V, 440 V AC; nominal system Uo\/Un 230\/400 V AC.<\/li>\n<li>Pluggable cartridge with thermal disconnector and green\/red status window.<\/li>\n<li>\u0623\u0637\u0631\u0627\u0641 \u062a\u0648\u0635\u064a\u0644 RC \u0627\u062e\u062a\u064a\u0627\u0631\u064a\u0629 \u0644\u0625\u0634\u0627\u0631\u0627\u062a \u0627\u0644\u062d\u0627\u0644\u0629 \u0639\u0646 \u0628\u064f\u0639\u062f.<\/li>\n<li>Housing UL94 V-0, IP20 (built-in); 35 mm DIN rail mounting.<\/li>\n<li>Suitable for TN-S \/ TN-C \/ TT systems (correct L-N \/ N-PE wiring).<\/li>\n<li>Ideal as a <strong>\u062c\u0647\u0627\u0632 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0645\u0646 \u0627\u0644\u0646\u0648\u0639 1<\/strong> at the service entrance in coordinated SPD schemes.<\/li>\n<\/ul>\n<\/section>\n<section id=\"specs\">\n<h3>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/h3>\n<table>\n<thead>\n<tr>\n<th>\u0627\u0644\u0645\u0639\u0644\u0645\u0629<\/th>\n<th>\u0627\u0644\u0642\u064a\u0645\u0629<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0631\u0645\u0632 \u0627\u0644\u0645\u0646\u062a\u062c<\/td>\n<td>KYSPD-25T1-1P<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0641\u0626\u0629<\/td>\n<td>Type 1 \/ Class I SPD<\/td>\n<\/tr>\n<tr>\n<td>\u062c\u0647\u062f \u0627\u0644\u0646\u0638\u0627\u0645 \u0627\u0644\u0627\u0633\u0645\u064a (Uo\/Un)<\/td>\n<td>230 \/ 400 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u0642\u0635\u0649. \u062c\u0647\u062f \u0627\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0645\u0633\u062a\u0645\u0631 (Uc)<\/td>\n<td>320 \/ 385 \/ 440 V AC<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u064a\u0627\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0627\u0633\u0645\u064a (\u062f\u0627\u062e\u0644\u064a\u060c 8\/20 \u0645\u064a\u0643\u0631\u0648 \u062b\u0627\u0646\u064a\u0629)<\/td>\n<td>25 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062d\u062f \u0627\u0644\u0623\u0642\u0635\u0649. \u062a\u064a\u0627\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a (Imax\u060c 8\/20 \u03bcs)<\/td>\n<td>100 kA<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u064a\u0627\u0631 \u0627\u0644\u062a\u0641\u0631\u064a\u063a \u0627\u0644\u0627\u0646\u062f\u0641\u0627\u0639\u064a (Iimp\u060c 10\/350 \u0645\u064a\u0643\u0631\u0648 \u062b\u0627\u0646\u064a\u0629)<\/td>\n<td>25 kA per pole<\/td>\n<\/tr>\n<tr>\n<td>\u0645\u0633\u062a\u0648\u0649 \u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u062c\u0647\u062f (\u0644\u0623\u0639\u0644\u0649)<\/td>\n<td>~1.6\u20132.0 kV (by variant)<\/td>\n<\/tr>\n<tr>\n<td>\u0648\u0642\u062a \u0627\u0644\u0627\u0633\u062a\u062c\u0627\u0628\u0629<\/td>\n<td>&lt; 25 \u0646\u0627\u0646\u0648 \u062b\u0627\u0646\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<td>Follow Current Interrupt Rating<\/td>\n<td>100 A RMS<\/td>\n<\/tr>\n<tr>\n<td>\u062a\u0635\u0646\u064a\u0641 \u062a\u064a\u0627\u0631 \u0627\u0644\u062f\u0627\u0626\u0631\u0629 \u0627\u0644\u0642\u0635\u064a\u0631\u0629 (ISCCR)<\/td>\n<td>50 kA<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0635\u0645\u0627\u0645 \u0627\u0644\u0627\u062d\u062a\u064a\u0627\u0637\u064a (\u0628\u062d\u062f \u0623\u0642\u0635\u0649)<\/td>\n<td>315 A gL\/gG<\/td>\n<\/tr>\n<tr>\n<td>\u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/td>\n<td>-40 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 ... +70 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/td>\n<td>\u0633\u0643\u0629 DIN 35 \u0645\u0645 (EN 60715)<\/td>\n<\/tr>\n<tr>\n<td>Enclosure<\/td>\n<td>\u0628\u0644\u0627\u0633\u062a\u064a\u0643 \u062d\u0631\u0627\u0631\u064a\u060c UL94 V-0\u060c UL94 V-9<\/td>\n<\/tr>\n<tr>\n<td>\u062f\u0631\u062c\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629<\/td>\n<td>IP20 (\u0645\u062f\u0645\u062c)<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0625\u0634\u0627\u0631\u0629 \u0639\u0646 \u0628\u064f\u0639\u062f<\/td>\n<td>\u062c\u0647\u0627\u062a \u0627\u062a\u0635\u0627\u0644 RC \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631\u064a\u0629<\/td>\n<\/tr>\n<tr>\n<td>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631<\/td>\n<td>IEC 61643-11 \/ EN 61643-11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"wiring\">\n<h3>\u0627\u0644\u0623\u0633\u0644\u0627\u0643 \u0648\u0627\u0644\u0623\u0628\u0639\u0627\u062f<\/h3>\n<ul>\n<li>\u0645\u062e\u0637\u0637 \u0627\u0644\u062a\u0648\u0635\u064a\u0644: <em>kyspd-25t1-connection<\/em><\/li>\n<li><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1284\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-1P-wiring-diagram-300x276.png\" alt=\"SPD-T1-1P-wiring-diagram\" width=\"507\" height=\"466\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-1P-wiring-diagram-300x276.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-1P-wiring-diagram.png 533w\" sizes=\"auto, (max-width: 507px) 100vw, 507px\" \/><\/li>\n<li>\u0627\u0644\u0623\u0628\u0639\u0627\u062f: <em>kyspd-25t1-dimensions<\/em><\/li>\n<li><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1285\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-1P-Dimension-300x280.png\" alt=\"SPD-T1-1P-Dimension\" width=\"517\" height=\"482\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-1P-Dimension-300x280.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/SPD-T1-1P-Dimension.png 369w\" sizes=\"auto, (max-width: 517px) 100vw, 517px\" \/><\/li>\n<\/ul>\n<\/section>\n<section id=\"apps\">\n<h3>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h3>\n<ul>\n<li>Service entrance \/ main distribution (LPZ 0\u21921) \u2014 first stage <strong>\u062c\u0647\u0627\u0632 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0643\u0647\u0631\u0628\u0627\u0626\u064a \u0645\u0646 \u0627\u0644\u0646\u0648\u0639 1<\/strong>.<\/li>\n<li>Industrial &amp; commercial buildings with high lightning exposure.<\/li>\n<li>Upstream in coordinated protection with downstream Type 2 \/ Type 3 SPDs.<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq\">\n<h3>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h3>\n<details>\n<summary>Where should this SPD be installed?<\/summary>\n<p>At the service entrance or main distribution board, as the first protection stage.<\/p>\n<\/details>\n<details>\n<summary>Does it support TT and TN systems?<\/summary>\n<p>Yes, with proper wiring modes L-N and N-PE.<\/p>\n<\/details>\n<details>\n<summary>What backup fuse is required?<\/summary>\n<p>Maximum 315 A gL\/gG, as recommended in technical data.<\/p>\n<\/details>\n<details>\n<summary>Can it be replaced easily?<\/summary>\n<p>Yes, the cartridge is pluggable and field-replaceable.<\/p>\n<\/details>\n<details>\n<summary>Is remote monitoring available?<\/summary>\n<p>Yes, RC contacts are optional for status signaling.<\/p>\n<\/details>\n<details>\n<summary>What is the ISCCR rating?<\/summary>\n<p>50 kA short-circuit withstand capacity.<\/p>\n<\/details>\n<details>\n<summary>What happens if the module fails?<\/summary>\n<p>The thermal disconnector isolates it and the indicator turns red.<\/p>\n<\/details>\n<details>\n<summary>\u0645\u0627 \u0647\u064a \u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631 \u0627\u0644\u062a\u064a \u062a\u0644\u0628\u064a\u0647\u0627\u061f<\/summary>\n<p>IEC\/EN 61643-11 for surge protective devices.<\/p>\n<\/details>\n<\/section>\n<section id=\"cta\"><a href=\"\/ar\/contact-us\/\">\u0627\u062d\u0635\u0644 \u0639\u0644\u0649 \u0639\u0631\u0636 \u0623\u0633\u0639\u0627\u0631<\/a> \u00b7 Related: <a href=\"\/ar\/ac-mcb\/\">AC MCB<\/a>, <a href=\"\/ar\/manual-transfer-switch\/\">\u0645\u0641\u062a\u0627\u062d \u0627\u0644\u062a\u062d\u0648\u064a\u0644 \u0627\u0644\u064a\u062f\u0648\u064a<\/a><\/section>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"197\" data-end=\"269\">\n<p data-start=\"199\" data-end=\"269\"><strong data-start=\"199\" data-end=\"223\">Class I \/ Type 1 SPD<\/strong> for service entrance, 230\/400 V AC systems.<\/p>\n<\/li>\n<li data-start=\"270\" data-end=\"340\">\n<p data-start=\"272\" data-end=\"340\"><strong data-start=\"272\" data-end=\"314\">Impulse current Iimp 25 kA (10\/350 \u03bcs)<\/strong>, In 25 kA, Imax 100 kA.<\/p>\n<\/li>\n<li data-start=\"341\" data-end=\"428\">\n<p data-start=\"343\" data-end=\"428\"><strong data-start=\"343\" data-end=\"363\">Pluggable module<\/strong> with visual indicator, DIN-rail, optional remote signaling (RC).<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1578,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[31],"product_tag":[],"class_list":{"0":"post-1283","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ac-spd","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product\/1283","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/comments?post=1283"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media\/1578"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media?parent=1283"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1283"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1283"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1283"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}