{"id":1060,"date":"2025-09-04T06:56:52","date_gmt":"2025-09-04T06:56:52","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1060"},"modified":"2025-09-10T05:49:33","modified_gmt":"2025-09-10T05:49:33","slug":"dc-fuse-1000v-kypv-h2","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ar\/product\/dc-fuse-1000v-kypv-h2\/","title":{"rendered":"\u0645\u0635\u0647\u0631 \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f 1000 \u0641\u0648\u0644\u062a | \u0648\u0635\u0644\u0629 \u0645\u0635\u0647\u0631 KYPV-H2 gPV (\u0645\u0631\u0628\u0639 \u0627\u0644\u0647\u064a\u0643\u0644\u060c 200-315 \u0623\u0645\u0628\u064a\u0631)"},"content":{"rendered":"<section id=\"overview\">\n<h2>\u0644\u0645\u062d\u0629 \u0639\u0627\u0645\u0629<\/h2>\n<p>\u0625\u0646 <strong>KYPV-H2<\/strong> \u062c\u0633\u0645 \u0645\u0631\u0628\u0639 \u0627\u0644\u0634\u0643\u0644 <strong>\u0645\u0635\u0647\u0631 \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f 1000 \u0641\u0648\u0644\u062a<\/strong> (gPV) \u0627\u0644\u0645\u0635\u0645\u0645\u0629 \u0645\u0646 \u0623\u062c\u0644<br \/>\nphotovoltaic combiner box mains, ESS DC bus, and inverter input circuits. With a current range of<br \/>\n<strong>200\u2013315A<\/strong>, it offers reliable interruption of overloads and short circuits.<br \/>\nBuilt with a ceramic body, silver fuse element, and quartz-sand filling, it ensures a breaking capacity<br \/>\nof <strong>50 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631<\/strong>. \u0627\u0644\u062a\u062b\u0628\u064a\u062a \u0628\u0627\u0633\u062a\u062e\u062f\u0627\u0645<br \/>\n<a href=\"\/ar\/1000v-dc-fuse-holder-kypv-h0b-h3b\/\">KYPV-H2B fuse holder<\/a> for safe mounting.<\/p>\n<\/section>\n<section id=\"features\">\n<h2>\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n<ul>\n<li>\u062c\u0633\u0645 \u0645\u0631\u0628\u0639 \u0627\u0644\u0634\u0643\u0644 <strong>\u0648\u0635\u0644\u0629 \u0635\u0645\u0627\u0645\u0627\u062a gPVV<\/strong>, frame size H2, <strong>1000 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631<\/strong>.<\/li>\n<li>Focus keyword: <strong>\u0645\u0635\u0647\u0631 \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f 1000 \u0641\u0648\u0644\u062a<\/strong>, current range 200\u2013315A.<\/li>\n<li>\u0642\u062f\u0631\u0629 \u062a\u0643\u0633\u064a\u0631 \u0639\u0627\u0644\u064a\u0629 \u0644\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u0645\u0631: <strong>50 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631<\/strong>.<\/li>\n<li>Ceramic body, silver fuse element, quartz-sand arc quenching.<\/li>\n<li>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631:<br \/>\n<a href=\"https:\/\/webstore.iec.ch\/publication\/24554\" target=\"_blank\" rel=\"noopener\">IEC 60269-6<\/a>,<br \/>\n<a href=\"https:\/\/ulstandards.ul.com\/\" target=\"_blank\" rel=\"noopener\">UL 248-19<\/a>.<\/li>\n<li>\u062d\u0627\u0645\u0644 \u0645\u062a\u0648\u0627\u0641\u0642: <a href=\"\/ar\/1000v-dc-fuse-holder-kypv-h0b-h3b\/\">KYPV-H2B<\/a>.<\/li>\n<\/ul>\n<\/section>\n<section id=\"specs\">\n<h2>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/h2>\n<table class=\"spec-table\">\n<tbody>\n<tr>\n<th>\u0627\u0644\u0646\u0648\u0639<\/th>\n<td>gPV fuse link, square-body H2<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0641\u0648\u0644\u062a\u064a\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629<\/th>\n<td>1000 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0646\u0637\u0627\u0642 \u0627\u0644\u062d\u0627\u0644\u064a<\/th>\n<td>200\u2013315 A<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0642\u062f\u0631\u0629 \u0627\u0644\u0627\u0633\u062a\u064a\u0639\u0627\u0628\u064a\u0629<\/th>\n<td>50 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631 (\u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631)<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0625\u0646\u0634\u0627\u0621\u0627\u062a<\/th>\n<td>\u0623\u0646\u0628\u0648\u0628 \u0633\u064a\u0631\u0627\u0645\u064a\u0643\u060c \u0639\u0646\u0635\u0631 \u0641\u0636\u064a\u060c \u062d\u0634\u0648\u0629 \u0628\u0631\u0645\u0644 \u0627\u0644\u0643\u0648\u0627\u0631\u062a\u0632<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631<\/th>\n<td>IEC 60269-6\u061b IEC 60269-6\u061b UL 248-19\u061b GB\/T 13539-6<\/td>\n<\/tr>\n<tr>\n<th>\u062d\u0627\u0645\u0644 \u0645\u062a\u0648\u0627\u0641\u0642<\/th>\n<td><a href=\"\/ar\/1000v-dc-fuse-holder-kypv-h0b-h3b\/\">KYPV-H2B<\/a><\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/th>\n<td>PV combiner box mains, ESS DC bus, inverter DC input<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"dimensions\">\n<h2>\u0627\u0644\u0623\u0628\u0639\u0627\u062f<\/h2>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-1055\" src=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/H2B-D-300x142.png\" alt=\"dc fuse 1000v dimension \" width=\"541\" height=\"256\" srcset=\"https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/H2B-D-300x142.png 300w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/H2B-D-768x364.png 768w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/H2B-D-600x284.png 600w, https:\/\/cnkuangya.com\/wp-content\/uploads\/2025\/09\/H2B-D.png 904w\" sizes=\"auto, (max-width: 541px) 100vw, 541px\" \/><\/p>\n<figure data-file=\"kypv-h2-dim\" data-alt=\"KYPV-H2 dimension drawing\"><\/figure>\n<figure data-file=\"kypv-h2-time-current\" data-alt=\"KYPV-H2 time-current characteristic\"><\/figure>\n<\/section>\n<section id=\"applications\">\n<h2>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h2>\n<ul>\n<li>Main fuse in PV combiner boxes at 1000 V DC.<\/li>\n<li>Energy storage DC bus and battery coupling circuits.<\/li>\n<li>Inverter and DC\/DC converter input protection.<\/li>\n<li>Industrial DC distribution systems requiring 200\u2013315 A protection.<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq\">\n<h2>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n<div class=\"qa\">\n<h3>Q1. What is the current rating of KYPV-H2?<\/h3>\n<p>It covers 200\u2013315 A for PV and ESS DC circuits.<\/p>\n<h3>Q2. What holder should I use?<\/h3>\n<p>Install with the <a href=\"\/ar\/1000v-dc-fuse-holder-kypv-h0b-h3b\/\">KYPV-H2B<\/a> \u062d\u0627\u0645\u0644 \u0645\u0635\u0647\u0631 \u0645\u0631\u0628\u0639 \u0627\u0644\u0634\u0643\u0644.<\/p>\n<h3>Q3. What is the breaking capacity?<\/h3>\n<p>The KYPV-H2 fuse link has a 50 kA DC breaking capacity.<\/p>\n<h3>Q4. Which standards does it meet?<\/h3>\n<p>IEC 60269-6 and UL 248-19, suitable for PV applications.<\/p>\n<\/div>\n<\/section>\n<section id=\"cta\">\n<h2>\u0637\u0644\u0628 \u0639\u0631\u0636 \u0623\u0633\u0639\u0627\u0631<\/h2>\n<p>\u062a\u0628\u062d\u062b \u0639\u0646 \u0634\u062e\u0635 \u0645\u0648\u062b\u0648\u0642 \u0628\u0647 <strong>\u0645\u0635\u0647\u0631 \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f 1000 \u0641\u0648\u0644\u062a<\/strong> (KYPV-H2, 200\u2013315A)?<br \/>\n<a href=\"\/ar\/contact-us\/\">\u0627\u062a\u0635\u0644 \u0628\u0646\u0627<\/a> for engineering support and pricing.<\/p>\n<\/section>\n<section id=\"related-links\">\n<h2>\u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0643\u0647\u0631\u0648\u0636\u0648\u0626\u064a\u0629 \u0630\u0627\u062a \u0627\u0644\u0635\u0644\u0629<\/h2>\n<p>Combine with the <a href=\"\/ar\/1000v-dc-fuse-holder-kypv-h0b-h3b\/\">\u062d\u0648\u0627\u0645\u0644 \u0627\u0644\u0635\u0645\u0627\u0645\u0627\u062a 1000 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631<\/a>,<br \/>\n<a href=\"\/ar\/dc-spd\/\">\u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u0645\u0631<\/a>, \u0648<br \/>\n<a href=\"\/ar\/dc-switch-disconnector\/\">\u0645\u0641\u0627\u062a\u064a\u062d \u0641\u0635\u0644 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u0645\u0631<\/a> \u0641\u064a \u0627\u0644\u062f\u0627\u062e\u0644<br \/>\n<a href=\"\/ar\/pv-combiner-box\/\">\u0635\u0646\u0627\u062f\u064a\u0642 \u0627\u0644\u062a\u062c\u0645\u064a\u0639 \u0627\u0644\u0643\u0647\u0631\u0648\u0636\u0648\u0626\u064a\u0629<\/a>. \u0627\u0644\u0645\u0631\u062c\u0639<br \/>\n<a href=\"https:\/\/webstore.iec.ch\/publication\/24554\" target=\"_blank\" rel=\"noopener\">IEC 60269-6<\/a><br \/>\n\u0648 <a href=\"https:\/\/ulstandards.ul.com\/\" target=\"_blank\" rel=\"noopener\">UL 248-19<\/a> \u0644\u0644\u0627\u0645\u062a\u062b\u0627\u0644 \u0644\u0644\u0645\u0639\u0627\u064a\u064a\u0631.<\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"403\" data-end=\"489\">\n<p data-start=\"405\" data-end=\"489\"><strong data-start=\"405\" data-end=\"422\">\u0645\u0635\u0647\u0631 \u062a\u064a\u0627\u0631 \u0645\u062a\u0631\u062f\u062f 1000 \u0641\u0648\u0644\u062a<\/strong> (gPV), square-body H2 frame, typical current range <strong data-start=\"474\" data-end=\"486\">200\u2013315A<\/strong>.<\/p>\n<\/li>\n<li data-start=\"490\" data-end=\"592\">\n<p data-start=\"492\" data-end=\"592\">\u0642\u062f\u0631\u0629 \u0643\u0633\u0631 \u0639\u0627\u0644\u064a\u0629 <strong data-start=\"515\" data-end=\"527\">50 \u0643\u064a\u0644\u0648 \u0623\u0645\u0628\u064a\u0631 \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631<\/strong>, ceramic body, silver fuse element, quartz-sand arc quenching.<\/p>\n<\/li>\n<li data-start=\"593\" data-end=\"670\">\n<p data-start=\"595\" data-end=\"670\">\u064a\u062a\u0648\u0627\u0641\u0642 \u0645\u0639 <strong data-start=\"609\" data-end=\"636\">iec 60269-6 \/ IEC 60269-6 \/ UL 248-19<\/strong>; \u064a\u0646\u0627\u0633\u0628 <strong data-start=\"643\" data-end=\"667\">KYPV-H2B fuse holder<\/strong>.<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1357,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[27],"product_tag":[],"class_list":["post-1060","product","type-product","status-publish","has-post-thumbnail","product_cat-dc-fuse-pv-fuse","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product\/1060","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/comments?post=1060"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media\/1357"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media?parent=1060"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1060"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1060"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1060"}],"curies":[{"name":"\u062f\u0628\u0644\u064a\u0648 \u0628\u064a","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}