{"id":1025,"date":"2025-09-03T11:56:16","date_gmt":"2025-09-03T11:56:16","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1025"},"modified":"2025-09-10T05:45:46","modified_gmt":"2025-09-10T05:45:46","slug":"gpv-fuse-10x85-1500v","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ar\/product\/gpv-fuse-10x85-1500v\/","title":{"rendered":"gpv fuse 10&#215;85 1500V | PV Fuse Link 2\u201332A for Solar Protection"},"content":{"rendered":"<section id=\"overview\">\n<h2>\u0644\u0645\u062d\u0629 \u0639\u0627\u0645\u0629<\/h2>\n<p>\u0625\u0646 <strong>\u00a0fuse 10&#215;85<\/strong> is a <strong>1500V PV fuse link<\/strong> rated for 2\u201332A,<br \/>\ndesigned for large-scale solar arrays and ESS systems. It provides fast and reliable protection<br \/>\nagainst overload and short-circuit faults in DC circuits. Its ceramic body, silver fuse element,<br \/>\nand quartz-sand arc extinguishing guarantee safe operation even under high fault currents.<\/p>\n<\/section>\n<section id=\"features\">\n<h2>\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n<ul>\n<li><strong>gpv fuse 10&#215;85 1500V<\/strong>, rated current 2\u201332A.<\/li>\n<li>High breaking capacity gPV fuse link for solar PV systems.<\/li>\n<li>Ceramic body, silver fuse element, quartz-sand arc quenching.<\/li>\n<li>Ensures safe interruption of DC fault currents.<\/li>\n<li>\u0645\u0639\u062a\u0645\u062f \u0644\u062f\u0649 <strong>IEC 60269-6<\/strong> \u0648 <strong>UL 248-19<\/strong>.<\/li>\n<\/ul>\n<\/section>\n<section id=\"specs\">\n<h2>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/h2>\n<table class=\"spec-table\">\n<tbody>\n<tr>\n<th>\u0627\u0644\u0646\u0648\u0639<\/th>\n<td>\u0648\u0635\u0644\u0629 \u0635\u0645\u0627\u0645\u0627\u062a gPVV<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0641\u0648\u0644\u062a\u064a\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629<\/th>\n<td>1500 V DC<\/td>\n<\/tr>\n<tr>\n<th>Fuse Size<\/th>\n<td>10\u00d785 mm<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0646\u0637\u0627\u0642 \u0627\u0644\u062d\u0627\u0644\u064a<\/th>\n<td>2\u201332 A<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/th>\n<td>10\u00d785 fuse holder \/ base<\/td>\n<\/tr>\n<tr>\n<th>Construction<\/th>\n<td>Ceramic tube, silver fuse element, quartz-sand filling<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631<\/th>\n<td>IEC 60269-6; UL 248-19<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/th>\n<td>PV strings, combiner boxes, ESS, inverter DC side<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"diagram\">\n<h2>Diagrams &amp; Media<\/h2>\n<figure data-file=\"gpv-10x85-main\" data-alt=\"gpv fuse 10x85 1500V main view\"><\/figure>\n<figure data-file=\"gpv-10x85-dim\" data-alt=\"gpv fuse 10x85 dimensions drawing\"><\/figure>\n<figure data-file=\"gpv-10x85-curve\" data-alt=\"gpv fuse 10x85 time-current curve\"><\/figure>\n<p class=\"note\">Derating curves should be considered for ambient temperatures above 40 \u00b0C.<\/p>\n<\/section>\n<section id=\"applications\">\n<h2>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h2>\n<ul>\n<li>PV string fuse protection in 1500V systems.<\/li>\n<li>Combiner box branch fuse link for solar farms.<\/li>\n<li>ESS DC bus coupling and battery pack protection.<\/li>\n<li>Inverter and DC\/DC converter input side protection.<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq\">\n<section id=\"related-links\">\n<h2>Related PV Protection Components<\/h2>\n<p>To build a reliable DC protection system, our<br \/>\n<a href=\"\/ar\/dc-fuse\/\">\u0635\u0645\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u0645\u0631<\/a>,<br \/>\n<a href=\"\/ar\/pv-fuse\/\">PV fuses<\/a>,<br \/>\n<a href=\"\/ar\/dc-spd\/\">DC surge protective devices (DC SPD)<\/a>,<br \/>\n\u0648 <a href=\"\/ar\/dc-switch-disconnector\/\">\u0645\u0641\u0627\u062a\u064a\u062d \u0641\u0635\u0644 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u0645\u0631<\/a><br \/>\ncan be integrated with <a href=\"\/ar\/pv-combiner-box\/\">\u0635\u0646\u0627\u062f\u064a\u0642 \u0627\u0644\u062a\u062c\u0645\u064a\u0639 \u0627\u0644\u0643\u0647\u0631\u0648\u0636\u0648\u0626\u064a\u0629<\/a><br \/>\nfor safe solar array operation. For certifications and compliance,<br \/>\nrefer to <a href=\"https:\/\/webstore.iec.ch\/publication\/24554\" target=\"_blank\" rel=\"noopener\">IEC 60269-6<\/a>,<br \/>\n<a href=\"https:\/\/ulstandards.ul.com\/\" target=\"_blank\" rel=\"noopener\">UL 248-19<\/a>,<br \/>\nand the <a href=\"https:\/\/www.seia.org\/\" target=\"_blank\" rel=\"noopener\">\u062c\u0645\u0639\u064a\u0629 \u0635\u0646\u0627\u0639\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0634\u0645\u0633\u064a\u0629 (SEIA)<\/a>.<br \/>\nNeed support? <a href=\"\/ar\/contact-us\/\">\u0627\u062a\u0635\u0644 \u0628\u0646\u0627<\/a> for technical guidance and quotes.<\/p>\n<\/section>\n<h2>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n<div class=\"qa\">\n<h3>Q1. What is the voltage rating of the\u00a0 fuse 10&#215;85?<\/h3>\n<p>It is rated for 1500V DC applications.<\/p>\n<h3>Q2. What current range is available?<\/h3>\n<p>The gpv fuse 10&#215;85 is available in 2\u201332 A ratings.<\/p>\n<h3>Q3. Which standards does it comply with?<\/h3>\n<p>It complies with IEC 60269-6, UL 248-19, and GB\/T 13539-6.<\/p>\n<h3>Q4. What are the typical applications?<\/h3>\n<p>Large PV arrays, combiner boxes, ESS DC buses, and inverter DC inputs.<\/p>\n<h3>Q5. Can the\u00a0 fuse 10&#215;85 be used with any holder?<\/h3>\n<p>It is designed for 10\u00d785 fuse holders compatible with 1500V PV fuses.<\/p>\n<\/div>\n<\/section>\n<section id=\"cta\">\n<h2>Request a Quote<\/h2>\n<p>Need a <strong>gpv fuse 10&#215;85 1500V<\/strong> for your PV or ESS project?<br \/>\n<a href=\"\/ar\/contact-us\/\">\u0627\u062a\u0635\u0644 \u0628\u0646\u0627<\/a> today.<\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<ul>\n<li data-start=\"385\" data-end=\"466\">\n<p data-start=\"387\" data-end=\"466\"><strong data-start=\"387\" data-end=\"411\">gpv fuse 10&#215;85 1500V<\/strong>, rated 2\u201332A, designed for PV and ESS DC protection.<\/p>\n<\/li>\n<li data-start=\"467\" data-end=\"562\">\n<p data-start=\"469\" data-end=\"562\">High breaking capacity ceramic fuse tube with silver element and quartz-sand arc quenching.<\/p>\n<\/li>\n<li data-start=\"563\" data-end=\"644\">\n<p data-start=\"565\" data-end=\"644\">\u0645\u0639\u062a\u0645\u062f \u0644\u062f\u0649 <strong data-start=\"578\" data-end=\"605\">iec 60269-6 \/ IEC 60269-6 \/ UL 248-19<\/strong>, compatible with 10\u00d785 fuse holders<\/p>\n<\/li>\n<\/ul>","protected":false},"featured_media":1351,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[27],"product_tag":[],"class_list":{"0":"post-1025","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-dc-fuse-pv-fuse","8":"first","9":"instock","10":"shipping-taxable","11":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product\/1025","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/comments?post=1025"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media\/1351"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media?parent=1025"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1025"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1025"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1025"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}