{"id":1019,"date":"2025-09-03T11:41:21","date_gmt":"2025-09-03T11:41:21","guid":{"rendered":"https:\/\/cnkuangya.com\/?post_type=product&#038;p=1019"},"modified":"2025-09-09T06:30:57","modified_gmt":"2025-09-09T06:30:57","slug":"1500v-dc-fuse-kypv-63d","status":"publish","type":"product","link":"https:\/\/cnkuangya.com\/ar\/product\/1500v-dc-fuse-kypv-63d\/","title":{"rendered":"\u0635\u0645\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u0645\u0631 1500 \u0641\u0648\u0644\u062a | \u062d\u0627\u0645\u0644 \u0627\u0644\u0635\u0645\u0627\u0645\u0627\u062a KYPV-63D \u0644\u0644\u0635\u0645\u0627\u0645\u0627\u062a 10\u00d785 \u064814\u00d785"},"content":{"rendered":"<section id=\"overview\">\n<h2>\u0644\u0645\u062d\u0629 \u0639\u0627\u0645\u0629<\/h2>\n<p>\u0625\u0646 <strong>KYPV-63D<\/strong> integrates a <strong>1500V DC fuse<\/strong> with a robust base,<br \/>\nsupporting <strong>10\u00d785 mm and 14\u00d785 mm gPV fuse links<\/strong>.<br \/>\nIt is designed for high-power PV arrays, ground-mount solar farms, and ESS DC buses.<br \/>\nWith current ratings from 2\u201350A, it provides reliable protection against short-circuits and overloads<br \/>\nin demanding solar and storage applications.<\/p>\n<\/section>\n<section id=\"features\">\n<h2>\u0627\u0644\u0645\u064a\u0632\u0627\u062a \u0627\u0644\u0631\u0626\u064a\u0633\u064a\u0629<\/h2>\n<ul>\n<li><strong>1500V DC fuse<\/strong>, compatible with 10\u00d785 &amp; 14\u00d785 mm gPV fuse links.<\/li>\n<li>Rated current up to 50A, designed for high-power PV and ESS systems.<\/li>\n<li>DIN-rail mount base, single-pole design with quick latch.<\/li>\n<li>Ceramic fuse tube, silver element, quartz-sand arc quenching.<\/li>\n<li>\u0645\u0624\u0634\u0631 \u0627\u0644\u0635\u0645\u0627\u0645\u0627\u062a \u0627\u0644\u0645\u062d\u062a\u0631\u0642\u0629 \u0627\u0644\u0627\u062e\u062a\u064a\u0627\u0631\u064a (\u0645\u0639\/\u0628\u062f\u0648\u0646 \u0636\u0648\u0621).<\/li>\n<li>\u064a\u062a\u0648\u0627\u0641\u0642 \u0645\u0639 <strong>IEC 60269-6<\/strong> \u0648 <strong>UL 248-19<\/strong>.<\/li>\n<\/ul>\n<\/section>\n<section id=\"specs\">\n<h2>\u0627\u0644\u0645\u0648\u0627\u0635\u0641\u0627\u062a<\/h2>\n<table class=\"spec-table\">\n<tbody>\n<tr>\n<th>\u0627\u0644\u0641\u0648\u0644\u062a\u064a\u0629 \u0627\u0644\u0645\u0642\u062f\u0631\u0629<\/th>\n<td>1500 \u0641\u0648\u0644\u062a \u062a\u064a\u0627\u0631 \u0645\u0633\u062a\u0645\u0631<\/td>\n<\/tr>\n<tr>\n<th>Fuse Sizes<\/th>\n<td>10\u00d785 mm (2\u201332A), 14\u00d785 mm (30\u201350A)<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0642\u0646\u0646<\/th>\n<td>Up to 50 A depending on fuse link<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u062a\u0631\u0643\u064a\u0628<\/th>\n<td>\u0633\u0643\u0629 DIN 35 \u0645\u0645\u060c 1 \u0642\u0637\u0628<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0645\u0624\u0634\u0631<\/th>\n<td>\u0645\u062a\u0648\u0641\u0631 \u0645\u0639\/\u0628\u062f\u0648\u0646 \u0625\u0636\u0627\u0621\u0629<\/td>\n<\/tr>\n<tr>\n<th>\u0627\u0644\u0645\u0639\u0627\u064a\u064a\u0631<\/th>\n<td>IEC 60269-6\u061b IEC 60269-6\u061b UL 248-19\u061b GB\/T 13539-6<\/td>\n<\/tr>\n<tr>\n<th>\u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0627\u0644\u062a\u0634\u063a\u064a\u0644<\/th>\n<td>-40 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629 ... +90 \u062f\u0631\u062c\u0629 \u0645\u0626\u0648\u064a\u0629<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section id=\"diagram\">\n<h2>\u0627\u0644\u0631\u0633\u0648\u0645 \u0627\u0644\u0628\u064a\u0627\u0646\u064a\u0629<\/h2>\n<figure data-file=\"kypv-63d-main\" data-alt=\"1500V DC fuse KYPV-63D base main view\"><\/figure>\n<figure data-file=\"kypv-63d-dim\" data-alt=\"1500V DC fuse dimensions drawing 10\u00d785 \/ 14\u00d785\"><\/figure>\n<figure data-file=\"kypv-63d-wiring\" data-alt=\"1500V DC fuse wiring diagram for PV and ESS systems\"><\/figure>\n<\/section>\n<section id=\"applications\">\n<h2>\u0627\u0644\u062a\u0637\u0628\u064a\u0642\u0627\u062a<\/h2>\n<ul>\n<li>Ground-mount solar farm DC fuse protection.<\/li>\n<li>Energy storage system (ESS) DC bus coupling.<\/li>\n<li>Large commercial PV combiner boxes.<\/li>\n<li>Inverter and converter DC-side protection.<\/li>\n<\/ul>\n<\/section>\n<section id=\"faq\">\n<section id=\"related-links\">\n<h2>\u0645\u0643\u0648\u0646\u0627\u062a \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0627\u0644\u0643\u0647\u0631\u0648\u0636\u0648\u0626\u064a\u0629 \u0630\u0627\u062a \u0627\u0644\u0635\u0644\u0629<\/h2>\n<p>\u0644\u0628\u0646\u0627\u0621 \u0646\u0638\u0627\u0645 \u062d\u0645\u0627\u064a\u0629 \u0645\u0648\u062b\u0648\u0642 \u0628\u0647 \u0644\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u0645\u0631\u060c \u0641\u0625\u0646<br \/>\n<a href=\"\/ar\/dc-fuse\/\">\u0635\u0645\u0627\u0645\u0627\u062a \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u0645\u0631<\/a>,<br \/>\n<a href=\"\/ar\/pv-fuse\/\">\u0627\u0644\u0635\u0645\u0627\u0645\u0627\u062a \u0627\u0644\u0643\u0647\u0631\u0648\u0636\u0648\u0626\u064a\u0629<\/a>,<br \/>\n<a href=\"\/ar\/dc-spd\/\">\u0623\u062c\u0647\u0632\u0629 \u0627\u0644\u062d\u0645\u0627\u064a\u0629 \u0645\u0646 \u0632\u064a\u0627\u062f\u0629 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u0645\u0631 (DC SPD)<\/a>,<br \/>\n\u0648 <a href=\"\/ar\/dc-switch-disconnector\/\">\u0645\u0641\u0627\u062a\u064a\u062d \u0641\u0635\u0644 \u0627\u0644\u062a\u064a\u0627\u0631 \u0627\u0644\u0645\u0633\u062a\u0645\u0631<\/a><br \/>\n\u064a\u0645\u0643\u0646 \u062f\u0645\u062c\u0647\u0627 \u0645\u0639 <a href=\"\/ar\/pv-combiner-box\/\">\u0635\u0646\u0627\u062f\u064a\u0642 \u0627\u0644\u062a\u062c\u0645\u064a\u0639 \u0627\u0644\u0643\u0647\u0631\u0648\u0636\u0648\u0626\u064a\u0629<\/a><br \/>\n\u0644\u0644\u062a\u0634\u063a\u064a\u0644 \u0627\u0644\u0622\u0645\u0646 \u0644\u0645\u0635\u0641\u0648\u0641\u0629 \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0634\u0645\u0633\u064a\u0629. \u0644\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u0627\u0644\u0634\u0647\u0627\u062f\u0627\u062a \u0648\u0627\u0644\u0627\u0645\u062a\u062b\u0627\u0644,<br \/>\n\u0627\u0644\u0631\u062c\u0648\u0639 \u0625\u0644\u0649 <a href=\"https:\/\/webstore.iec.ch\/publication\/24554\" target=\"_blank\" rel=\"noopener\">IEC 60269-6<\/a>,<br \/>\n<a href=\"https:\/\/ulstandards.ul.com\/\" target=\"_blank\" rel=\"noopener\">UL 248-19<\/a>,<br \/>\n\u0648 <a href=\"https:\/\/www.seia.org\/\" target=\"_blank\" rel=\"noopener\">\u062c\u0645\u0639\u064a\u0629 \u0635\u0646\u0627\u0639\u0627\u062a \u0627\u0644\u0637\u0627\u0642\u0629 \u0627\u0644\u0634\u0645\u0633\u064a\u0629 (SEIA)<\/a>.<br \/>\n\u0647\u0644 \u062a\u062d\u062a\u0627\u062c \u0625\u0644\u0649 \u062f\u0639\u0645\u061f <a href=\"\/ar\/contact-us\/\">\u0627\u062a\u0635\u0644 \u0628\u0646\u0627<\/a> \u0644\u0644\u062d\u0635\u0648\u0644 \u0639\u0644\u0649 \u0627\u0644\u0625\u0631\u0634\u0627\u062f\u0627\u062a \u0627\u0644\u0641\u0646\u064a\u0629 \u0648\u0639\u0631\u0648\u0636 \u0627\u0644\u0623\u0633\u0639\u0627\u0631.<\/p>\n<\/section>\n<h2>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/h2>\n<div class=\"qa\">\n<h3>Q1. What fuse sizes does KYPV-63D support?<\/h3>\n<p>It supports 10\u00d785 mm (2\u201332A) and 14\u00d785 mm (30\u201350A) gPV fuse links.<\/p>\n<h3>Q2. What is the rated voltage of this fuse?<\/h3>\n<p>The KYPV-63D is rated for 1500V DC operation.<\/p>\n<h3>Q3. Is a blown-fuse indicator available?<\/h3>\n<p>Yes, optional versions with or without indicator light are available.<\/p>\n<h3>Q4. What standards does it comply with?<\/h3>\n<p>IEC 60269-6 \u0648 UL 248-19 \u0648 GB\/T 13539-6.<\/p>\n<h3>Q5. Where is the 1500V DC fuse commonly applied?<\/h3>\n<p>Large PV farms, ESS DC buses, and high-power inverter DC-side protection.<\/p>\n<\/div>\n<\/section>\n<section id=\"cta\">\n<h2>\u0637\u0644\u0628 \u0639\u0631\u0636 \u0623\u0633\u0639\u0627\u0631<\/h2>\n<p>Need a reliable <strong>1500V DC fuse<\/strong> for your PV or ESS system?<br \/>\n<a href=\"\/ar\/contact-us\/\">\u0627\u062a\u0635\u0644 \u0628\u0646\u0627 \u0627\u0644\u064a\u0648\u0645<\/a>.<\/p>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>1500V DC fuse solution compatible with 10\u00d785 mm &amp; 14\u00d785 mm gPV fuse links (2\u201350A).<\/p>\n<p>High-capacity DIN-rail holder, ceramic tube with quartz sand, optional indicator.<\/p>\n<p>Certified to IEC 60269-6 \/ UL 248-19, ideal for large PV and ESS DC bus systems.<\/p>","protected":false},"featured_media":1278,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[27],"product_tag":[],"class_list":["post-1019","product","type-product","status-publish","has-post-thumbnail","product_cat-dc-fuse-pv-fuse","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product\/1019","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/comments?post=1019"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media\/1278"}],"wp:attachment":[{"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/media?parent=1019"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_brand?post=1019"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_cat?post=1019"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/cnkuangya.com\/ar\/wp-json\/wp\/v2\/product_tag?post=1019"}],"curies":[{"name":"\u062f\u0628\u0644\u064a\u0648 \u0628\u064a","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}