DC Circuit Breaker 2P 500V 125A | KYDB-125-2P

  • Kuangya KYDB-125-2P is a dc circuit breaker 2p 500v 125a, available in 63A / 80A / 100A / 125A.

  • Provides dependable overload & short-circuit protection with 6kA breaking capacity.

  • Double-pole DIN-rail breaker, IEC 60947-2 certified, for PV, ESS & industrial systems.

Get A Quotation

Category:

Overview

The dc circuit breaker 2p 500v 125a (model KYDB-125-2P) is a double-pole miniature DC breaker engineered for solar PV combiner boxes, energy storage (ESS), and industrial DC distribution systems. Rated for 500VDC and available in 63A / 80A / 100A / 125A, it ensures overload and short-circuit protection with a 6kA breaking capacity. Ui 690V and Uimp 6kV provide strong insulation performance for demanding environments.

Key Features

  • Rated voltage: 500VDC (2P); frame current: 125A
  • Current options: 63A / 80A / 100A / 125A
  • Breaking capacity: 6kA (Icn/Ics)
  • Trip characteristics: C / D, thermal-magnetic
  • Insulation & impulse: Ui 690V; Uimp 6kV
  • Endurance: Mechanical life 20,000 ops; Electrical life 2,000 ops
  • Compliance: IEC 60947-2, GB/T 14048.2; CE & UL
  • Works with PV combiner boxes, DC fuses, DC SPDs, and DC switch disconnectors

Specifications

ModelKYDB-125-2P
Poles2P
Rated Current (In)63A / 80A / 100A / 125A
Rated Voltage (Ue)500VDC
Rated Insulation Voltage (Ui)690V
Impulse Withstand Voltage (Uimp)6kV
Breaking Capacity (Icn/Ics)6kA / 6kA
Trip CharacteristicsC / D
Mechanical Life20,000 operations
Electrical Life2,000 operations
InstallationDIN-rail, width 36mm (18mm × 2 poles)
StandardsIEC 60947-2, GB/T 14048.2

Wiring Diagram & Dimensions

125A-MCB DIMENSION

 

Applications

  • Solar PV combiner boxes
  • Energy storage system (ESS) DC buses
  • Industrial DC distribution panels
  • Telecom and infrastructure DC power supply

FAQ

Q1: What is a dc circuit breaker 2p 500v 125a?

A1: It is a double-pole miniature DC breaker rated at 500VDC and up to 125A, providing overload and short-circuit protection.

Q2: What current ratings are available?

A2: KYDB-125-2P supports 63A, 80A, 100A, and 125A.

Q3: What is the breaking capacity?

A3: Standard breaking capacity is 6kA (Icn/Ics).

Q4: Can it be used in PV and ESS systems?

A4: Yes, this dc circuit breaker 2p 500v 125a is commonly applied in PV combiner boxes and ESS systems.

Q5: Which standards does KYDB-125-2P comply with?

A5: It complies with IEC 60947-2, GB/T 14048.2, CE, and UL certifications.

Get a Quote

Contact Kuangya for datasheets, wiring diagrams, or OEM customization of KYDB-125-2P.